MD-7300D Stationary DR HIGH FREQUENCY DIGITAL X RAY MACHINE (Double Column Flat Table WiFi Detector)

Products > RADIO > MD-7300D Stationary DR HIGH FREQUENCY DIGITAL X RAY MACHINE (Double Column Flat Table WiFi Detector)

MD-7300D Stationary DR HIGH FREQUENCY DIGITAL X RAY MACHINE (Double Column Flat Table WiFi Detector)

Product Usage
MD-7300D high frequency digital x-ray equipment can meet different parts radiography, such as head, chest, abdomen, waist, lumber, thoracic, pelvis, limbs etc. And meet different positions radiography, such as lay decubitus, normotopia, side position etc. it is fixed digital x ray machine and we can use it at bus and truck.

Basic Configuration

Configuration

Model No

Quantity

Remarks

Control Console

KZT10

1 unit

MD-

High voltage generator

FSQ60

1 set

MD-

X-ray tube assembly

E7252X

1 unit

Canon

Collimator

XSQ30

1 unit

MD-

Radiography Table

SYC20

1unit

MD-

Bucky Stand

XPJ30

1 set

MD-

Detector

MD--1717V

1 set

MD-

Image acquisition workstation

DRA20

1 set

MD-

Color display

P1917S

1 unit

DELL

Machine accessories

MD-7300

1 set

MD-

AEC

SSMC601

1 set

Optional

 Product Specification

Item

Content

Technical Parameters

Power

Voltage

380V±10%

Frequency

50Hz±1Hz

Capacity

≥65kVA

Internal Resistance

≤0.17Ω

High Frequency High Voltage X-Ray Generator

Power

56KW

Inverter Frequency

440 KHz

Tube voltage

40kV—150kV ,Steps 1kV

Tube current

10mA—710mA

Exposure time

1ms—10000ms

mAs

0.1-900mAs

X-ray source assembly

(TOSHIBA E7252X)

Input power

Big focus 75kW Small focus 27kW

Anode thermal capacity

210KJ

Anode maximum heat dissipation

475W667KHU/min

Rotary anode speed

9700rpm

Tube Focus:big/small

1.2mm /0.6mm

China WiFi Flat Panel DetectorMD--1717V

Active area

427(H)×427(V)

Pixel matrix

3072(H)×3072(V)

Pixel pitch:

139 μm

Limiting resolution

3.1 lp/mm type

A / D transition:

14 bit

Energy range

40 - 150 kVp

Maximum entrance dose (low gain)

4 mR / frame

Power Input:

DC 24V 2A

Collimator (XSQ30)

View light:

Light Halogen, AC24V/100W

Visible light exposure brightness Average illumination   brightness: >100Lux

Illuminator turn-on time limit up to 30±2S

Bucky Stand XPJ30

Up and down movement

Not less than 1300mm

Table SYC20

SID

500~1280mm

Table bearing

135kg

 

Image acquisition workstation DRA20

Computer system

Processor: Intel Core Quad Core Processor i5-6500 (3.20 GHz)

Memory: 4 GB DDR3L

Hard disk: 1T SATA (7200rpm)

Optical drive: DVD-RW disc burner

Display: P1917S 19 "Dell

Workstation software

Basic skills:

Registration: new patient; emergency registration; appointment registration; RIS registration;

Local database: Set query conditions; sort the query results and modify the title bar.

Check: edit patient basic information; output patient check; close check; delete registered check; protect existing check; multi-protocol check; add, delete and copy position in check; reject captured image; restore rejected image; Switch between.

Additional functions: adjust the exposure parameters and exposure sequence; save the adjusted exposure parameters; adjust the orientation of the X-ray tube and the buck; plate status indication; exposure status display; generator control; image preview.

Image processing functions: LUT curve and symphony image processing; view patient and exposure dose information; image arbitrary and custom size cropping; add body position and arbitrary markers; add notes information; image selection; image scaling; image partial magnification; window width window ; image movement; image inversion; clockwise rotation; counterclockwise rotation; vertical flip; horizontal flip; window display; 1:1 display; 1X1 layout; 1X2 layout; 2X2 layout; 4X4 layout; distance measurement; angle measurement; image reset ; image deletion; brightness adjustment; black and white adjustment; image reprocessing; image queue transmission and export; image printing, printing film typesetting; image film scaling.

System management functions: workstation information; user management; emergency registration settings; information statistics; detector calibration; configuration tools.

User Management: Add User; User Permission Settings; User Password Modification; Delete User.

Emergency registration settings: new emergency registration; delete emergency registration; modify emergency registration information; default inspection protocol.