Product Configuration List:

Name

Brand

Quantity

Remark

X ray High Frequency High Voltage Generator

FSQ30V

1 set

PLD

X ray Tube

E7239X

1 set

Canon

Collimator

XSQ30

1 set

PLD

Radiography table

SYC60

1 set

PLD

Digital Flay Panel Detector

CareView 1800CW

1 set

CareView

DR Acquisition Workstation

DRA40

1 set

PLD

Complete machine accessories

VET1800B

1 set

PLD

 

Production Parameters:

VET1800B

Content

Technical   file

Power Supply

Voltage

220V±22V

Frequency

50Hz±1Hz

Capacity

5kVA

Internal   resistance

0.4Ω

High Frequency and High Voltage Generator

Power   output

20kW

Inverter   frequency

500kHz

Radiography   tube voltage

40kV-125kVStep1KV  

Radiography   tube current

10mA-250mA

Radiography   time

1ms-10000ms  

Control   interface

Integrated   in image workstation

Radiography   mAs

0.2~100mAs


Capacitor   charging and discharging time

20S

X ray tube assemblyE7239X

Output   power

Big focus   42.5kW   small focus 21kW

Anode heat   capacity

100kJ140KHU

Maximum   heat dissipation of anode

475W667HU/s

Component   heat capacity

900kJ1250KHU

Rotating   anode speed

Minimum 2700min-1

Tube Focus:   Big Focus/Small Focus

2.0/1.0

Collimator device

(XSQ30)

Collimator   light

Halogen   lamp24V/100W

Visible   light illumination brightness

Average   illuminance>100Lux

Power   supply

24VAC±1.2V/6.5A

Weight

7.5KG

Radiography table

Longitudinal moving   range of bed surface

500mm

Bed transverse   movement range 

Fixed

SID

1000mm

Moving Range of   radiography  Box

Fixed

Longitudinal Moving   Range pillar

Fixed

Table height from the   ground    

700mm

Table size

1410mm×670mm

Workstation

KZT10


No caseKZT10B

Flat Panel DetectorCareView 1800L

Image   sensor

Cesium   iodide

Pixel size

154μm

Effective pixel size

2816*2816   mm

Effective area (H x V)

434*434mm

Image transmission

Gigabit Ethernet (GbitE)

Gray scale

16bit

Spatial resolution

3.4Lp/mm

Cycle time

4-5s

Energy range

40kV to 150kV

Power input

AC 220V 50HZ

DR Collection workstation

DRA40

Basic   function

Newly build patient; newly build examination; anonymous   registration; WorkList retrieval and advanced retrieval; WorkList refresh;   WorkList information import; checklist; view image; film printing; writing   report.

Collection   function

Window width and position adjustment; 90 °   left rotation; 90 ° right rotation; horizontal   mirror; vertical mirror; image negative; clipping box; exposure parameter   setting; bulb focus switch; exposure mode selection; ionization chamber   selection; exposure actual dose value; system status indicator.

Image   viewing function

Image   zoom; local zoom; original size; Restore window size; image grid display; 90 °   left rotation; 90 ° right rotation; horizontal   mirror; text mark; line mark; angle mark; arrow mark; clipping box; rectangle   mark; circle mark; polygon mark; length correction; four corner information   display; ruler display; window width and window position adjustment; sequence   image broadcast Put; image output; silhouette function; delete image; image   enhancement; reload image; image negative.


Film   printing function

Add   image; insert image; delete image; clear image; image layout; image   selection; print format; film print settings; film format settings; add,   modify, delete printer settings.


Report   editing function

Open   report; save report; Export Report; add report; delete report; print preview;   printer settings; report template editing; image list; add report template;   delete case template.


Service   function

Daily   settings: system settings; check protocol editing; system log settings; load   user configuration.

Advanced   settings: restart system; IR settings; IR correction; problem finding;   hardware settings; backup recovery; language settings.