MD-6000 High Frequency Digital X-ray Machine

Products > Fluoroscopy x-ray unit > MD-6000 High Frequency Digital X-ray Machine

MD-6000 High Frequency Digital X-ray Machine

MD-6000 High Frequency Digital X-ray Machine

The unit is available for medical teaching, research, medical units for gastrointestinal X-ray spot film photography, remote control compartment, fluoroscopy and other 
Traumatic Radiography etc of X-ray routine examination, Can be used for gastrointestinal imaging, cholangiography, Urinary tract imagingand Deep vein imaging and other imagings ; Can used for fluoroscopy of esophagus, breast, gastrointestine, Abdomen and limbs and spot film photography; Can do the operation of Fracture reduction and Taking foreign body from in vivo .

 

Main Features :
Diagnostic table
1)·Visual display of man-machine interface, touch screen control, makes man-machine conversation more intuitive, convenient and easy to understand.
·2)Programmable controller technology, high control precision, good stability, excellent anti-jamming performance
·3)Inverter control technology, When the table move, it can soft start, soft stop, smooth no noise, more accurate positioning
·4)Reliable, high precision of angular displacement sensor technology, low dynamic noise, and long mechanical life.
·5)High-resolution of rotary encoders, high accuracy of auto-slice, security and stability.
·6)Rotation range of 90 ° ~ 0 ° ~ -25 °, can take routine examination of digestive organs , can also be used for a variety of special examination
·7)Humanized Design of diagnostic table lateral switch , near station positioning make the operation more convenient.
·8)Toshiba's high-quality image intensifier, to further enhance image sharpness, contrast, more easily, to clearly identifyLesions.
·9)Move a wide range of spot film device, apply the operation fo People do not move with the operation of motor way easily to complete taking from the throat, esophagus,To the lower abdomen of a series of examinations .
·10)Spot film box open on their own, safe and reliable operation.
2. Generator
•1)With X-ray Radiography and perspective function of generator, maximum output power of 50 kW.
•2)Output voltage of 150 kV.
•3)With a smaller, lighter, modular design.
•4)In the exposure process, kV and mA can be adjusted to achieve a constant radiation output.
•5)Large-screen LCD flat panel used to display the APR conventional conditions and practical projects.
•6)User-friendly system configuration.
•7)Operator can modify the APR technology items.
•8)Provide APR /-ray tube data downloads.
•9)A variety of automated diagnostic procedures, and operators with prompts
.•10)With serial RS232 communication interface
•11)Operation can be individually programmed for the APR, and APR and manual techniques for programming options
•12)Programmable settings, calibration, and conduct regular APR (by connecting an external computer).
•13)For ABS (Automatic Brightness Stabilization) circuit select four kinds of kV and mA curve.

 

Main Specifications of MD-6000 High Frequency Digital diagnostic Medical X-ray Equipment


Item
Content
Specification
Power
Voltage
380V±38V
Frequency
50Hz±1Hz
Capacity
≥65kVA
Internal resistance
≤0.17Ω
Digital x-ray high voltage system
original imported CPI high frequency high voltage generator

Power
50KW
Radiography
Tube voltage
40kv—150kv  bracket adjust
Tube current
10mA—630mAbracket adjust
Exposure time
1.0s—6300ms bracket adjust
Control interface
Touch LCD Screen
Fluoroscopy 
Tube voltage
40kv—125kv  2kv/step continuously adjust
Tube current
0.5mA—6mA continuously adjust
Digital control x-ray tube(Toshiba of Japan)
Model
E7252
Focus :large/small
1.2mm /0.6mm
Input power
Large focus 75kW   small focus 27kW
Heat capacity of anode
210KJ(300KHU)
Rotary anode speed 
2700rpm
Microcomputer controlled digital upper tube remote control diagnosis table
Rotary range of the table
90°~0°~-25°
Horizontal movement range of the table
±110mm
Vertical movement of Radiography frame and spot film device
≥720mm
Focus and film distance of the x-ray tube
1100 mm—1500 mm
Radiography size of the whole film
8″×10 ″—14″×17″
Partition mode of spot film
Whole film, two films, three films, four films
Control mode of diagnosis table
Remote control, table control,frequency conversion
 collimator       
Electrical multi-leaf type
Fixed grid of table use
Grid density: 103L/INCH,Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15″×18″
Digital image TV system
Image intensifier
Toshiba 9”
High resolution CCD (digital camera)
Imported high sensitivity 470000pixel or 1 million pixel   
Monitor
14〞medical high definition monitor, horizontal central resolution ratio :1000 lines,fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame
Digital image processing system(CCU central control)
 
High definition line by line output mode, 8 level noise reduction,store 8 image;LIH(freeze the last frame),the image can be turned vertically and horizontally,positive and negative image; OSD(monitor show)