MD-5000B 500mA X-ray Radiograph system

Products > Fluoroscopy x-ray unit > MD-5000B 500mA X-ray Radiograph system

MD-5000B 500mA X-ray Radiograph system

MD-5000B 500mA X-ray Radiograph system

Specifications:
  

Power Output                     : 40KW                       

    X-ray Tube                          : Rotary anode 

    Focus                                  : 1.0mm

    Thermal Capacity              : 140 KJ 

    Commute Method             : Full Wave Commutation 

    Tube Voltage                      : 50~125KV,interval 1KV 

    Tube Current                     : 32mA(min) ~500 mA (max) Adjustable 

                                                    with different grades 

    Exposure Time                  : 0.020s~4.000s(23 grades) 

    Bucky grid                           : Grid Density                 : 40L/cM

                                                   Grid Ratio                      : 10:1

                                                   Focus Distance            : 120cm

                                                   Stationary Dimension : 15″×18″ 

    Power Supply                    : Two Phases with Four Lines(380V±10%,

                                                   50Hz Inner-resistance≤0.3Ω Capacity

                                                   ≥40KVA) 

Structure 

    Bed Size                             : 2000×760mm 

    Bed Height                         : ≤700mm 

    Bed Transverse Movement Distance                    : ±110mm 

    Bed Longitudinal Movement Distance                  : ±450mm 

    Cassette Movement Distance                                : ≥500mm 

    X-ray Generator Revolution around Pillar Center: ±90° 

    Pillar Turning                                                              : 40°×9° 

    Pillar Movement Range along Bed                        : ≥1300mm 

    Distance Between Focus and Film(SID)              : 500~1280mm 

    Time Limit of Collimator Lamp                               : 15sec 

    Vertical Movement of Sternum Plank                     : 480~1460mm 

    Film Size                             : 5"×7"~14"×17"

Bed                                  :2200mm×1100mm×900mm     

                                           N.W. 300kgs  G.W.425kgs

Oil trunk                           :800mm×700mm×1050mm            

                                           N.W. 300kgs  G.W.375kgs

Operation   table            :1200mm×1000mm×1700mm 

                                            N.W. 350kgs  G.W.450kgs

Bucky stand                     :2440mm×1100mm×900mm    

                                             N.W. 250kgs  G.W.375kgs

Features:

1. Anti-electroshock, radiation-proof, and full wave commutation.

2. With electromagnetism controlling system, fluctuation bed board

    and manual operation pillar to ensure a fast and reliable

    location. 

3. Structure designed based on anthropotomy, with beautiful

    appearance, and easy to operate.

4. Convenient to take stretcher photograph. 

5. A sternum plank is optional (grid density: 40L/cm; grid ratio:

   10:1; focus distance: 120cm;stationary, dimension: 15″×18″,

   and distance adjustable)

PLD998 Bucky Stand

Features:

1.Compact figuration; Fine structure and nice and novel sculpt

2.Using hand-ring bolt to fix, occupying little space and easy to operate.

3.Short distance between film and panel makes the distortion of photograph

 very small.

4.Korea-made ray-filtration grid brings a perfect articulation and contrast.